Affected Version: BioStar 2.9.6 or above
Affected Products & Versions:
BioStation 3 Firmware Version 1.3.0 to be released at the end of June 2024
FaceStation F2 Firmware Version 2.2.0 to be released in August 2024
Overview
When integrating Suprema product with third-party controllers via Wiegand major 3rd party controllers are designed to send the same authentication feedback multiple times, which causes Suprema device to go in a loop.
In order to cancel out (ignore) repetitive (continuous) authentication signals being sent from the 3rd party controllers after the same authentication signal at the first time, using BioStar 2 Trigger and Action feature in the device by determining the duration to ignore repeated signals based on particular firmware with this feature. This customized firmware with the usage of BioStar 2 software ensures Suprema device to not replay the authentication signal multiple times for a single authentication event.
How to set up Ignore Repeated Signals Duration feature
MUST USE PROPER FIRMWARE FOR THIS FEATURE
CHECK YOUR BioStation 3 Firmware to be greater than 1.3.0, and for FaceStation F2 to be greater than 2.2.0
If not follow this link ▶ and upgrade your firmware FIRST
After checking/ upgrading firmware to proper version
- Go to BioStar 2 → Device → Click on the particular device → Check the firmware version
- Device → Advanced → Trigger & Action → +Add
※ If [Ignore Repeated Signals Duration (ms)] is set to 0 (zero), repated signals will not get ignored.
※ The [Ignore Repeated Signals Duration (ms)] value can be set from 0 to 10,000 milliseconds
※ The Default value for [Ignore Repeated Signals Duration (ms)] is 0.
Video Guide