Affected Versions: BioStar 2 version 2.8.14 ~ BioStar 2 version 2.9.1

Fixed Version: to be released in BioStar 2 version 2.9.2

Summary 

Even when user sets certain timeout session value using BioStar 2 software, and also manually make the changes in system.conf file, session expiration occurs within two to three hours in BioStar 2 version 2.8.14~ version 2.9.1


Relevant Issue Description 

User has changed session Timeout value from [default session timeout value: 1hour] to another value as shown in the image 600 Min



Main Cause of the issue 

Every time when BioStar 2 restarts then it automatically gets reset to default value which is 3,6000 seconds = 60 minutes = 1hour for session timeout


Workaround 

Please contact technical support, to receive session timeout bug fixed patch file for other BioStar 2 Version   
Make a request by creating a new ticket in Tech Support Portal 
Available patch file versions: BioStar 2 Version 2.8.16 & BioStar 2 Version 2.9.0
BioStar 2 Version 2.8.16_ssession_timeout_fixed_bug_patchfile
BioStar 2 Version 2.9.0_session_timeout_fixed_bug_patchfile