Prerequisits for Suprema Plugin
I. License
1. Software license
1) Genetec
- Security Center : 1ea
- SDK Connection : GSC-1SDK-SUPREMA-READ (One license supports 2 connection)
i) Config Tool login: 2ea
ii) Security desk login : 1ea
iii) Suprema extractor plugin: 1ea per Genetec Security Center Server
iv) Suprema device plugin: 1ea per Suprema device plugin
* One device plugin supports up to 4 cloud links (256 Suprema devices),
and you can add as many Suprema Device Plugin as you need
> Needs total 3 GSC-1SDK-SUPREMA-READ per Server
2) Suprema
- Plugin license: INT_GEN_GSC
1. Device license
1) Genetec
- GSC-Sy-X-1R(E) : 1ea per device assigned to door as reader
2) Suprema
- Only devices that it's ID is registered in Server license can be registered in Plugin
- Sku: Device model - GEN
II. Database
1. Permission for SQL database
* To ensure proper operation of the Plugin (Device Plugin and Extractor DB),
please grant the SQL account the following permissions:
2. Database size requirements
* The required database storage capacity varies depending on the number of users enrolled with biometric data. When face templates are enrolled, the Suprema Extractor Plugin generates and stores the corresponding templates in its Database.
Each face template requires approximately 104 kB of database space.
Ensure that sufficient storage capacity is allocated based on the expected number of biometric users.

III. RIO protocol
* To ensure proper operation of the Plugin, please enable RIO protocol for Synergis Cloud Link or Softwire
Process
1. Enter the folowing URL into your browser
- https://[Unit IP]/Features/DuiRIO/Enabled/Set?value=true
2. Login to Synergis Cloud Link or Softwire 
3. Click a RUL http://[IPaddress]//Features/DuiRIO/Enabled/Ser?value=treu

* Check point. : When the RIO protocol is enabled, the RIO tab becomes available on the Hardware page under
Config Tool > Access Control > Cloud Link.

V. Profile image quality setting
* If you'd like to extract face templates from cardholder profile images in GSC,
please adjust picture size to ensure picture quality
Path: Config Tool _ Access Control _ General settings

IV. Device setting
1) Removing all users and logs from devices
2) Factory reset devices
3) Set User ID type as Alphanumeric
* Default IP and PW for device admin
ID: su
PW: 1234
> You can change PW from Config Tool _ Suprema Plugin Configuration _ Superadmin Credential page